- Measuring range | 0.1-25.0% O2 |
- Accurracy | O2<10.0% ± 0.01%at 2% O2, O2>10.0% ± 0.1% |
- Linearity | <0.5% FS |
- Lag time | <2 sec. |
- Response time | <5 sec. |
- Warm-up time | <30 min. |
- Zero Drift | ±2% of range per month |
- Span Drift | ±2% of range per month |
- Power supply | 100-240 VAC 50-60 Hz |
- Power consumption | <100 VA warmp up, <50 VA steady state |
- Output | 4-20 mA |
- Max. load, analogue output | 500 Ω |
- Max. load, relay contacts | 220 VAC 5 Amp. |
- Max. ambient temperature | 0-50ºC |
- Max. humidity | 90% RH |
- Enclosure | IP 65 |
- Dimensions old (HxWxD) | 400 x 300 x 210 mm |
- Dimensions new (HxWxD) | 300 x 380 x 210 mm |
- Weight | 10 kg with housing ( 2 kg without housing and probe |
| MARITIME version ) |
- Certification | DNV |
Probe Technical Specifications | |
- Max. stack gas temperature | 500ºC |
- Sensor type | ZrO2 (Zirconia) |
- Material | AISI 316 Stainless steel |
- Mounting | 3" Withworth pipe thread DIN ISO 228 |
- Total lenght | 250 mm (502 probe) (short version) 140 mm (OM10 probe) |
| 730 mm Variable 200-500 mm EPL 1500 max. insert lenght 1500 mm |
- Cable lenght | max. 10 m. (502 probe) excl. stack unit max. 2 m (OM10 probe) |
- Weight | 2,0 kg (502 probe) (short version) 0,2 kg (OM10 probe) |
| 4 kg (502 probe) (long version) |