Ozon analyser

Model GM 6000 RTI Ozon Analyser

Model GM 6000 RTI Ozon Analyser

Measuring principle NDUV 253,7 nm - Photometer
Range 000.1 - 299.9   gO3/Nm3
Accuracy <1% of scale end
Size (mm) H 120 x W 320 x D 300
Response time < 1 s
Output 0/4 - 20 mA, linear
Display resolution 0.1  g O3 / m3
Extinction coefficient 3024 dm3/cm mol (DIN 19627)
Flow rate 30 l/h
Noise 0,1 %
Gas connector 4,3 / 3 mm PTFE / SS
Gas pressure max 2.5 bar abs. (36 psia)
Supply voltage Internal 110 /240 VAC , 50/60 Hz
Weight 3,2 kg
Accessory Handle to carry and for desk pos.
Catalyst Metal oxide with heater and filter
Certified EC 17025, CEN / TR 14740, DKD
Approved CE

Model GM 6000 OEM Ozon Analyser

Model GM 6000 OEM Ozon Analyser

Measuring principle UV 253,7 nm - Photometer
Range 000.1 - 199.9   gO3/ m3 (SI-Unit)
Accuracy <1% of scale end
Size (mm) H 72 x W 144 x D 230
Response time < 1 s
Output 0/4 - 20 mA, linear
Display resolution 0.1  g O3 / m3
Extinction coefficient 3024 dm3/cm mol (DIN 19627)
Flow rate 30 l/h
Noise 0,1 %
Gas connector 4,3 / 3 mm PTFE / SS
Gas pressure max 2.5 bar abs. (36 psia)
Supply voltage Internal 110 /240 VAC , 50/60 Hz
Weight 1,7 kg
Accessory Panel chips
Optics

Ozone free quartz UV lamp, interference

filter 254 nm, high quality O3 UV mirror

Protection class IP 65, NEMA 12
Certificates CEN / TR 14740 ,  CE
Model GM 6000 PRO Ozon Analyser

Model GM 6000 PRO Ozon Analyser

Measuring principle

non-dispersive UV absorption (Lambert-

Beer): approved optical system

Range

000.1 - 199.9   /  0.001 - 1.999 g O3/m3

000.1 - 299.9  /  00.01  -  19.99 g O3/m3

Measurment units g O3/m3 , g O3/Nm3, % w/w, ppmw,ppmv
Repeatability +/- 0.2% of scale end (SCE)
Accuracy +/- 0.2% of scale end (SCE)
Zero drift automatic zero drift correction
Temperature drift automatic offset drift correction
Span drift automatic span drift correction (optional)
Outputs (programmable)

0-20mA, 4-20mA, alternatively 0-1V,

0-10V (RS232 interface)

Built-in alarms  (programmable)

4 treshold alarms, 1 main alarm,  1 flow

control (optional) 1 alarm lamp,

1 audible alarm (optional)

Programmable parameters

measurement unit - scaling factor

adjustment conditions- alarm parameters

-molecular weight of carrier gas- and

several other parameters on request

Configuration IP54, IP65,  wall-panel-rackmount
Power supply

100-120 / 220-240 VAC 50-60 Hz

(selectable)

Display

graphic LCD module with CFL illumination

size 126 x 37 mm  (5" x 145")

Keyboard foil keyboard, integrated in front panel
Approved CE
Model MP Ozon Analyser

Model MP Ozon Analyser

Measuring principle single-beam-photometer
Range

0-1 ppmv, -0-10 ppmv, 0-100 ppmv

other measuring ranges on request

(switchable) 0-1 mg O3/Nm3, 0-10 mg O3/Nm3
Sensitivity 0.001 ppmv
Zero drift automatically digitally autozeroed
Precision 0.010 ppmv (<1%)
Linearity 99,8%
Concentration units

ppmv, pphmv, mg O3/Nm3, g O3/Nm3

mg O3/m3, g O3/m3, % by weight w/w

Display 1 x 20 characters, aplha numeric, LCD
Gas flow rate      /   Flow detection 100 - 200 NI  /h         /    optional
Analog signal 0/4 - 20 mA
Digital signal RS 232 (bi-directional)
Alarm signal 4 x potential-free contact, changeable
Diagnostic signal

internal diagnostic system with 6 error

notifications & alarm

Dimensions Standard 19" / 3 HU rack mountable
Sample ports 1/4 "
Supply voltage 110 / 240 VAC , 50/60 Hz
Approval CE
Model Sen Pocket Ozon gas sensor

Model Sen Pocket Ozon gas sensor

Measuring procedure Electrochemical measuring cell (EC)
Alarm 3 instantaneous alarms
Measuring gas inlet Diffusion
Climate conditions -20 ... +50 (40) ºC / 5 .... 95% rH/700...1300 hPa
Operation time up to 6 months
Battery type Duracell Procell MN 1500 LR6 AA
Protection class IP 56
Measuring range 0.01 ppm  -  1.00 ppm
Examination II 2G EEx ib IIC T4 bzw. T3-20ºC Ta<45ºC bzw
Certification EC-type exam. certificate DMT 99 ATEX E 044
Weight 84 g
Dimensions 47 x 88 x 25 mm
Model SEN6060 Sensor

Model SEN6060 Sensor

Measuring principle Amperometric 2-electrode sensor
Measuring range 0.01 - 1.00 ppm
Response time t (50) : < 60 s      t (90) : < 200 s
Operation conditions - 20ºC ..... + 40ºC
Size H x W x D     95 x 145 x 50 mm
Weight 650 g
Display resolution 122 X 32 pixels (illuminated display)
Sensitivity drift < 5% per month
Temperature drift < 10%
Temperature dependence Electronic compensation
Model WP Ozon Water Analyser

Model WP Ozon Water Analyser

Measuring principle single-beam photometer with desorber
Measuring range

0.001 - 1.999 mg O3/m3  H2O 00.01 - 19.99 mg O3/m3

H2O 000.1 - 199.9 mg O3/m3  H2O 0.001 - 1.999 g O3/

m3 H2O (2ppmw) 00.01 - 19.99 g O3/m3  H2O 000.1 -

199.9 g O3/m3 H2O

Zero drift Automatically digitally autozeroed
Precision 0.010 ppmv (< 1%)
Linearity 99,8%
Concentration units ppmw  -   ppbw
Display 1 x 20 character, alpha-numeric, LCD
Water flow rate 810  I / h
Analog signal 0/4 - 20 mA
Digital signal 0/4 - 20 mA
Alarm signal 4 x potential-free change-over contact
Diagnostic signal Internal diagnostic system with 6 error notif. & alarm
Sample ports DN 10
Supply voltage 110 / 240 VAC, 50/60 Hz
Approvals CE, CEN / TR 14740, CEN / TC164, DIN 19627
Ozon Water System PAP5000

Ozon Water System PAP5000

Applications:

  • Bottling Systems

  • Sterilization of potable water

  • Ozone rinsing systems

  • Without bromate formation.

SPECS: UNITSPAP5000PAP10000PAP30000
Water flow m³/h5.710.030.0
Tank volume liter500500500
Power supply V/Hz400/50-3ph. 50 H400/50-3ph. 50 H400/50-3ph. 50 H
Water connections Inch24

Features :

Ready for operationNo toxic off-gas by using catalystControlled ozone generator
No chemicals neededUsing oxygen as feed gas - no formation of nitrogen oxydesMeasuring signals ready for data recorder
Oxygen will be generated out of ambient airTank out of stainless steel 

 

 

Model ChemLogic Portable Gas Detector  ( CLPX ) is een draagbare, door

een microprocessor bestuurde monitor meter

Kleurmetrisch papier-tape-detectie en reflecterende lichtniveaumeting.

De CLPX is automatisch en zelfcalibrerend en één van de betrouwbaarste,Model ChemLogic Portable Gas Detector  ( CLPX )

gebruikersvriendelijke gasdetectors op de markt.

Industrieën die isocyanaten produceren gebruiken deze monitor.

Een bijzonderheid is het functionele display, met membraam-stijl schakelaars, dat toegang

geeft tot alle gebruiksfuncties zonder bijkomende dure hardware of software.
 

  • Grote nauwkeurigheid, voorzien van een interne klok voor onderzoek concentratieniveau's

     of  voor  elke monstername.

  • Blootstellingsniveau kan worden gedownloaded via kabel naar elke computer (Windows).
  • Geen gepatenteerde hardware/software nodig.
  • Veelzijdige monitor, kan ook worden geconfigureerd voor andere gassen door andere

      cassettes te gebruiken.

  • Hoorbaar - en zichtbaar alarm.
     
  • Te meten gassen:  Arsine, CHDI, HDI, HMDI, Hydrazine, IPDI, MDI, MMH, PDI, TDI, Phosgene, Ozon, H2SE, HCN, SO2, HNO3, PH3, BF3, Diborane en germane  in ppb.

     CLO2, HCI, H2S, NH3, NF3, HF, HBr, Silane in ppm.

 

 8000 Series   AccuSafe SeriesChloor Chloordioxide RM series

Model

8000 Series

AccuSafe Series

RM Series

                                            Specificaties 8000                                           Specificaties AccuSafe                                     specificatie RM series

Nieuwsbrief

Wilt u op de hoogte blijven van het laatste nieuws? Meld u dan aan voor onze nieuwsbrief!