Zuidbuurtseweg 42 | 2381 LG Zoeterwoude | T: 071 580 93 08 | F: 071 580 21 54 | E: info@envico.nl

slide1-Envico-Environment-Control-B.V.-Ammonia-analyse slide2-Envico-Environment-Control-B.V.-Emissiemeting slide3-Envico-Environment-Control-B.V.-Gasanalyse slide4-Envico-Environment-Control-B.V.-Gasdetectie slide5-Envico-Environment-Control-B.V.-Nox-analyser slide6-Envico-Environment-Control-B.V.-Noxmeting slide7-Envico-Environment-Control-B.V.-Stofmeting

Ozon analyser

   

Model GM 6000 RTI Ozon Analyser

 

 
 
 
 
 
Measuring principle                             NDUV 253,7 nm - Photometer
Range 000.1 - 299.9   gO3/Nm3
Accuracy <1% of scale end
Size (mm) H 120 x W 320 x D 300
Response time < 1 s
Output 0/4 - 20 mA, linear
Display resolution 0.1  g O3 / m3
Extinction coefficient 3024 dm3/cm mol (DIN 19627)
Flow rate 30 l/h
Noise 0,1 %
Gas connector 4,3 / 3 mm PTFE / SS
Gas pressure max 2.5 bar abs. (36 psia)
Supply voltage Internal 110 /240 VAC , 50/60 Hz
Weight 3,2 kg
Accessory Handle to carry and for desk pos.
Catalyst Metal oxide with heater and filter
Certified EC 17025, CEN / TR 14740, DKD
Approved CE
 
 
 
 

Model GM 6000 OEM Ozon Analyser

 
 

 

 

 

 

Measuring principle                             UV 253,7 nm - Photometer
Range 000.1 - 199.9   gO3/ m3 (SI-Unit)
Accuracy <1% of scale end
Size (mm) H 72 x W 144 x D 230
Response time < 1 s
Output 0/4 - 20 mA, linear
Display resolution 0.1  g O3 / m3
Extinction coefficient 3024 dm3/cm mol (DIN 19627)
Flow rate 30 l/h
Noise 0,1 %
Gas connector 4,3 / 3 mm PTFE / SS
Gas pressure max 2.5 bar abs. (36 psia)
Supply voltage Internal 110 /240 VAC , 50/60 Hz
Weight 1,7 kg
Accessory Panel chips
Optics

Ozone free quartz UV lamp, interference 

filter 254 nm, high quality O3 UV mirror 

Protection class IP 65, NEMA 12
Certificates CEN / TR 14740 ,  CE

 

 

 

 

Model GM 6000 PRO Ozon Analyser

 

 

Measuring principle                            

non-dispersive UV absorption (Lambert-

Beer): approved optical system

Range

000.1 - 199.9   /  0.001 - 1.999 g O3/m3

000.1 - 299.9  /  00.01  -  19.99 g O3/m3 

Measurment units g O3/m3 , g O3/Nm3, % w/w, ppmw,ppmv
Repeatability +/- 0.2% of scale end (SCE)
Accuracy +/- 0.2% of scale end (SCE)
Zero drift automatic zero drift correction
Temperature drift automatic offset drift correction
Span drift automatic span drift correction (optional)
Outputs (programmable)

0-20mA, 4-20mA, alternatively 0-1V,

0-10V (RS232 interface)

Built-in alarms  (programmable)

4 treshold alarms, 1 main alarm,  1 flow

control (optional) 1 alarm lamp, 

1 audible alarm (optional)

Programmable parameters

measurement unit - scaling factor 

adjustment conditions- alarm parameters

-molecular weight of carrier gas- and

several other parameters on request

Configuration IP54, IP65,  wall-panel-rackmount
Power supply 

100-120 / 220-240 VAC 50-60 Hz 

(selectable)

Display

graphic LCD module with CFL illumination
 

size 126 x 37 mm  (5" x 145")

Keyboard foil keyboard, integrated in front panel
Approved  CE
 

 

 

Model MP Ozon Analyser

 

 

Measuring principle                             single-beam-photometer
Range

0-1 ppmv, -0-10 ppmv, 0-100 ppmv

other measuring ranges on request

(switchable) 0-1 mg O3/Nm3, 0-10 mg O3/Nm3
Sensitivity  0.001 ppmv
Zero drift automatically digitally autozeroed
Precision 0.010 ppmv (<1%)
Linearity 99,8%
Concentration units

ppmv, pphmv, mg O3/Nm3, g O3/Nm3

mg O3/m3, g O3/m3, % by weight w/w

Display 1 x 20 characters, aplha numeric, LCD
Gas flow rate      /   Flow detection 100 - 200 NI  /h         /    optional
Analog signal 0/4 - 20 mA
Digital signal RS 232 (bi-directional)
Alarm signal 4 x potential-free contact, changeable
Diagnostic signal

internal diagnostic system with 6 error

notifications & alarm

Dimensions Standard 19" / 3 HU rack mountable
Sample ports 1/4 "
Supply voltage 110 / 240 VAC , 50/60 Hz
Approval CE
 

 

 

Model Sen Pocket Ozon gas sensor

                                                                                                

Measuring procedure                        Electrochemical measuring cell (EC)
Alarm 3 instantaneous alarms
Measuring gas inlet Diffusion
Climate conditions                                           -20 ... +50 (40) ºC / 5 .... 95% rH/700...1300 hPa
Operation time up to 6 months
Battery type Duracell Procell MN 1500 LR6 AA
Protection class  IP 56
Measuring range 0.01 ppm  -  1.00 ppm
Examination  II 2G EEx ib IIC T4 bzw. T3-20ºC Ta<45ºC bzw
Certification  EC-type exam. certificate DMT 99 ATEX E 044
Weight 84 g
Dimensions 47 x 88 x 25 mm

 

 

Model SEN6060 Sensor

 

 

 

 

Measuring principle                                                        Amperometric 2-electrode sensor           
Measuring range 0.01 - 1.00 ppm
Response time t (50) : < 60 s      t (90) : < 200 s
Operation conditions - 20ºC ..... + 40ºC
Size H x W x D     95 x 145 x 50 mm
Weight 650 g
Display resolution 122 X 32 pixels (illuminated display)
Sensitivity drift < 5% per month
Temperature drift < 10%
Temperature dependence Electronic compensation

 

 

 

Model WP Ozon Water Analyser

 

 

Measuring principle              single-beam photometer with desorber 
Measuring range                           

0.001 - 1.999 mg O3/m3  H2O 00.01 - 19.99 mg O3/m3

H2O 000.1 - 199.9 mg O3/m3  H2O 0.001 - 1.999 g O3/

m3 H2O (2ppmw) 00.01 - 19.99 g O3/m3  H2O 000.1 -

199.9 g O3/m3 H2O

Zero drift Automatically digitally autozeroed
Precision 0.010 ppmv (< 1%)
Linearity 99,8%
Concentration units ppmw  -   ppbw
Display 1 x 20 character, alpha-numeric, LCD
Water flow rate 810  I / h
Analog signal 0/4 - 20 mA
Digital signal 0/4 - 20 mA
Alarm signal 4 x potential-free change-over contact
Diagnostic signal Internal diagnostic system with 6 error notif. & alarm
Sample ports DN 10
Supply voltage 110 / 240 VAC, 50/60 Hz
Approvals  CE, CEN / TR 14740, CEN / TC164, DIN 19627

 

 

 

 

Ozon Water System PAP5000

 

Applications:

 - Bottling Systems                                                                                                                                                  - Sterilization of potable water                                                                                                                                - Ozone rinsing systems                                                                                                                                        - Without bromate formation.

SPECS: UNITS    PAP5000 PAP10000 PAP30000
Water flow m³/h 5.7 10.0 30.0
Tank volume liter 500 500 500
Power supply V/Hz 400/50-3ph. 50 H 400/50-3ph. 50 H 400/50-3ph. 50 H
Water connections Inch 2 4

 

Features:

Ready for operation No toxic off-gas by using catalyst Controlled ozone generator
No chemicals needed  Using oxygen as feed gas - no formation of nitrogen oxydes Measuring signals ready for data recorder
Oxygen will be generated out of ambient air Tank out of stainless steel  

 